Reliable temperature measurement begins with selecting the right temperature instrument-specifically, the temperature sensor. Thermocouples, thermistors, platinum resistance thermometers (RTDs), and temperature ICs are among the most commonly used sensors for this purpose.
The following is an overview of the characteristics of thermocouples and thermistors.
1. Thermocouples
Thermocouples are the most widely used temperature sensors. Their primary advantages include a wide operating temperature range and suitability for various atmospheric environments; they are also rugged, inexpensive, require no external power supply, and represent the most cost-effective option. A thermocouple consists of two dissimilar metal wires (Metal A and Metal B) joined at one end; when this junction is heated, a potential difference is generated within the circuit. This measured potential difference can be used to calculate the temperature.
However, the relationship between voltage and temperature is non-linear. Consequently, a second measurement of a reference temperature (Tref) is required, and the voltage-to-temperature conversion must be processed-either via software or hardware within the instrument-to determine the actual thermocouple temperature (Tx). The Agilent 34970A and 34980A data acquisition systems both feature built-in measurement and processing capabilities.
In short, while thermocouples are the simplest and most versatile temperature sensors, they are not suitable for applications requiring high precision.
2. Thermistors
Thermistors are made from semiconductor materials and typically exhibit a negative temperature coefficient (NTC), meaning their resistance decreases as temperature rises. Because temperature fluctuations cause significant changes in resistance, they are the most sensitive type of temperature sensor. However, thermistors suffer from extremely poor linearity, and their characteristics depend heavily on the manufacturing process; consequently, manufacturers cannot provide standardized resistance-versus-temperature curves.
Thermistors are very small and respond quickly to temperature changes. However, they require a current source for operation, and their compact size makes them highly susceptible to self-heating errors.
Thermistors measure absolute temperature and offer good accuracy, but they are more expensive than thermocouples and have a narrower measurement range. A common type of thermistor has a resistance of 5 kΩ at 25°C, with a resistance change of 200 Ω for every 1°C change in temperature. Note that the 10Ω lead resistance introduces a negligible error of only 0.05°C. This makes it highly suitable for current-controlled applications requiring rapid, sensitive temperature measurements. While its compact size is advantageous for space-constrained applications, care must be taken to prevent self-heating errors.
Thermistors come with their own specific measurement considerations. Their small size is an advantage, allowing for rapid stabilization without imposing a thermal load; however, this also makes them fragile, and high currents can lead to self-heating. As resistive devices, thermistors generate heat when a current flows through them-a result of power dissipation calculated as the product of the square of the current and the resistance. Consequently, low-current sources should be used. Exposure to excessive heat can cause permanent damage to the thermistor.
We hope this overview of these two types of temperature-sensing devices proves helpful in your work and studies.