Liaoning Yifang Wisdom Technology Group Co., Ltd. is one of the leading manufacturers and suppliers of ftp cable cat6 in China. We are committed to offering high quality customized products for global clients. Please feel free to wholesale the newest ftp cable cat6 in stock here from our factory. For quotation, contact us now.
ftp cable cat6

Basic Information
High-speed network transmission faces severe stability challenges in industrial and electromechanical intensive environments. Ordinary Cat6 UTP unshielded cables have no anti-interference protection, making them extremely susceptible to signal coupling from frequency converters, high-power motors and dense power lines. External electromagnetic noise easily causes high delay, random packet loss and signal distortion, resulting in blurred high-definition monitoring images, industrial control signal lag and system offline failures. Low-grade shielded cables on the market adopt discontinuous foil shielding, unstandardized twisting structure and lack core cross-isolation design, leading to simultaneous defects of external interference penetration and internal crosstalk overflow, which cannot sustain long-term stable 10G high-speed transmission.
Our upgraded Cat6 FTP shielded cable solves all core pain points of industrial high-speed networking. It adopts a dual protection structure of internal cross skeleton isolation + overall aluminum foil full shielding. The physical cross skeleton separates four pairs of twisted cores independently, effectively suppressing internal near-end crosstalk and delay skew, ensuring clean and synchronous high-speed signal transmission. The fully wrapped aluminum foil shielding layer cooperates with tinned copper drain wire to form a complete grounding shielding system, isolating external industrial electromagnetic interference in all directions. Adopting 23AWG high-purity oxygen-free solid copper conductor, it features ultra-low resistance and minimal signal attenuation, stably supporting 250MHz wide bandwidth, 1000Mbps full-range gigabit transmission at 100m and 10Gbps ultra-high-speed transmission within 55m. All cables pass professional Fluke full-bandwidth performance testing, with industrial-grade anti-aging and wear-resistant sheath, adapting to harsh on-site laying conditions and realizing long-term reliable high-speed anti-interference network operation.
Features And Optional Customization
Tailored for industrial automation high-speed networking and high-noise high-bandwidth engineering projects, this Cat6 FTP cable integrates high-speed performance and industrial anti-jamming capabilities, with outstanding comprehensive adaptability:
Dual anti-interference design eliminates internal crosstalk and external electromagnetic noise at the same time, solving the long-standing problem of unstable high-speed network in industrial sites. 250MHz ultra-wide bandwidth supports multi-terminal concurrent access and large-flow data transmission, meeting the bandwidth demand of high-definition video, cloud data and industrial real-time control signals. High-purity oxygen-free copper core ensures zero attenuation of high-speed signals, avoiding network speed downgrade and bandwidth bottlenecks after long-distance laying. Full compatibility with PoE and PoE+ protocols realizes stable integration of power supply and data transmission, adapting to industrial high-power monitoring cameras, wireless APs and edge intelligent terminals.
It supports diversified personalized customization: PVC industrial wear-resistant sheath and LSZH low-smoke flame-retardant sheath are optional to adapt to conventional workshops and fire-standard closed spaces. Cable length, outer diameter and sheath color can be customized to unify on-site engineering specifications. High-flexibility customized version is available for repeated bending and movable equipment wiring. Standard boxed and bulk packaging supports large-scale centralized engineering procurement.

Technical Specification
|
Core Performance Parameters |
|
|
Executive Standard |
ANSI/TIA-568.2-D, ISO/IEC 11801 Class E Cat6 Certified |
|
Bandwidth Performance |
250MHz industrial high bandwidth, support high-load data transmission |
|
Transmission Capacity |
1000Mbps@100m stable gigabit, 10Gbps@55m high-speed transmission |
|
Structural Design |
4-Pair precision twisted pair + cross skeleton isolation + full aluminum foil shielding + tinned copper drain wire |
|
Conductor Specification |
23AWG 99.95%+ high-purity oxygen-free solid bare copper |
|
Core Advantages |
Dual anti-crosstalk, strong EMI shielding, low latency, stable PoE operation |
|
PoE Compatibility |
Full adaptation to PoE/PoE+ power and data synchronous transmission |
|
Application Value |
Stabilize high-speed network in industrial noisy environments, reduce equipment failure rate |
Material & Industrial Design
- Conductor: High-purity oxygen-free solid copper core, ultra-low resistivity, low signal attenuation
- Insulation Layer: High-density HDPE polyethylene insulation, stable dielectric properties, no signal distortion
- Shielding System: Continuous full-coverage aluminum foil + standard tinned copper grounding drain wire, 360° anti-interference
- Isolation Structure: Reinforced rigid cross skeleton, physical separation of wire pairs to suppress high-speed crosstalk
- Outer Sheath: Wear-resistant & anti-aging industrial PVC / LSZH low-smoke flame-retardant optional
- Factory Testing: Fluke full-bandwidth test, electromagnetic interference resistance test, tensile and aging durability test
Application Area
Industrial workshop automated equipment high-speed networking, electrical control room integrated cabling, factory high-definition PoE monitoring system, data center anti-interference high-speed link, intelligent building high-bandwidth weak-current engineering, and other high-electromagnetic-interference and low-delay demanding scenarios.
Available Design
- Dual sheath options: PVC for general industrial sites, LSZH for fire-proof, smokeless and enclosed public environments
- Custom cable length, jacket color and outer diameter to match project unified standards
- High-flexibility customized version for frequently bent and mobile equipment connection
- 305m standard boxed packaging / bulk packaging for large-scale engineering projects
Similar Product Recommendation
For ordinary indoor low-interference high-speed wiring, select Cat6 UTP Network Cable. For cost-effective industrial gigabit anti-interference wiring, choose Cat5e FTP Cable. For extreme strong electromagnetic interference environments, upgrade to Cat6 SFTP double-shielded cable.

Why Choose Us
Most on-site industrial high-speed network failures stem from electromagnetic interference and internal high-speed crosstalk. Different from ordinary Cat6 UTP cables without shielding and inferior broken-shield FTP cables, our Cat6 FTP cable adopts dual-core optimization of cross isolation and full foil shielding. It completely solves the defects of easy jitter and packet loss of high-speed signals in industrial high-noise environments. The standard 23AWG pure copper core ensures true Cat6 high-bandwidth performance without attenuation or speed drop. Strict Fluke factory testing guarantees stable 10Gbps short-distance and full-range gigabit transmission quality. With reliable PoE power supply stability and industrial durable structure, it balances high-speed performance and anti-interference capability, being the most cost-effective and reliable high-speed shielded cabling solution for industrial automation and commercial high-bandwidth projects.
Customer Service
We provide complete product datasheets, Class E standard certification reports and engineering wiring guidelines. Our professional technical team supports pre-sales scenario matching and personalized parameter customization, as well as after-sales equipment debugging and long-term stable technical support, ensuring continuous and stable high-speed network operation of on-site equipment.

FAQ
Q: What is the core difference between Cat6 FTP and Cat6 UTP?
A: Cat6 UTP is unshielded and only suitable for low-noise indoor environments. Cat6 FTP adds full aluminum foil shielding and standard grounding drain wire, which can effectively resist industrial EMI/RFI electromagnetic interference, ensuring stable low-latency high-speed transmission in equipment-intensive workshops and electrical rooms.
Q: Does Cat6 FTP support PoE and PoE+ equipment?
A: Yes. The professional shielding structure will not affect power transmission efficiency. It fully supports PoE/PoE+ synchronous power and data transmission, stably driving industrial high-power monitoring and wireless terminal equipment.
Q: What are the speed and transmission distance specifications?
A: It supports stable 1000Mbps full 100-meter gigabit transmission and 10Gbps ultra-high-speed transmission within 55 meters, fully meeting industrial and commercial high-speed network engineering standards.
Q: When should I choose Cat6 FTP instead of SFTP?
A: Cat6 FTP has cost-effective comprehensive anti-interference performance, suitable for most industrial workshops and electrical room interference scenarios. SFTP double-shielded cable is only required for extreme super-strong electromagnetic interference environments.
Hot Tags: ftp cable cat6, China ftp cable cat6 manufacturers, suppliers